Awarded as the best online publication by CIDC

Mix Design For M35 Grade Of Concrete

The mix design for M35 Grade Of Concrete for pile foundations provided here is for reference purpose only. Actual site conditions vary and thus this should be adjusted as per the location and other factors.

Grade of Concrete : M35
Characteristic Strength (Fck) : 35 Mpa
Standard Deviation : 1.91 Mpa*
Target Mean Strength : T.M.S.= Fck +1.65 x S.D.
(from I.S 456-2000) = 35+ 1.65×1.91
= 38.15 Mpa

Test Data For Material:
Aggregate Type : Crushed
Specific Gravity
Cement : 3.15
Coarse Aggregate : 2.67
Fine Aggregate : 2.62

Advertisements

Water Absorption:
Coarse Aggregate : 0.5%
Fine Aggregate : 1.0 %

MIX DESIGN

Take Sand content as percentage of total aggregates = 36%

Select Water Cement Ratio = 0.43 for concrete grade M35

(From Fig 2. of I.S. 10262- 1982)

Select Water Content = 172 Kg

(From IS: 10262 for 20 mm nominal size of aggregates Maximum Water Content = 186 Kg/ M3 )

Hence, Cement Content= 172 / 0.43 = 400 Kg / M3

Formula for Mix Proportion of Fine and Coarse Aggregate:

1000(1-a0) = {(Cement Content / Sp. Gr. Of Cement) + Water Content +(Fa / Sp. Gr.* Pf )}

1000(1-a0) = {(Cement Content / Sp. Gr. Of Cement) + Water Content +Ca / Sp. Gr.* Pc )}

Where Ca = Coarse Aggregate Content

Fa = Fine Aggregate Content

Pf = Sand Content as percentage of total Aggregates

= 0.36

Pc = Coarse Aggregate Content as percentage of total Aggregates.

= 0.64

a0 = Percentage air content in concrete (As per IS :10262 for 20 mm nominal size of

aggregates air content is 2 %) = 0.02

Hence, 1000(1-0.02) = {(400 /3.15) + 172 +(Fa / 2.62 x 0.36)}

Fa = 642 Kg/ Cum

As the sand is of Zone II no adjustment is required for sand.

Sand Content = 642 Kg/ Cum

1000(1-0.02) = {(400 /3.15) + 172 +(Ca / 2.67 x 0.64)}

Hence, Ca = 1165 Kg/ Cum

From combined gradation of Coarse aggregates it has been found out that the proportion of 53:47 of 20 mm & 10 mm aggregates produces the best gradation as per IS: 383.

Hence, 20 mm Aggregates = 619 Kg

And 10 mm Aggregates = 546 Kg

To obtain slump in the range of 150-190 mm water reducing admixture brand SP430 from Fosroc with a dose of 0.3 % by weight of Cement shall be used.

Advertisements

Hence the Mix Proportion becomes:

Cem

W/C

Water

Sand

20mm

10mm

Admix

400

0.43

172

635

619

564

1.2

1

0.43

1.6

1.547

1.36

0.003

Units – Kg/ M3

Cement : Sand: Coarse Aggregates = 1 : 1.6 : 2.907

We are thankful to Er. Ishan Kaushal for this valuable information.

Share this post

Kanwarjot Singh

Kanwarjot Singh is the founder of Civil Engineering Portal, a leading civil engineering website which has been awarded as the best online publication by CIDC. He did his BE civil from Thapar University, Patiala and has been working on this website with his team of Civil Engineers.

If you have a query, you can ask a question here.

152 comments on "Mix Design For M35 Grade Of Concrete"

DEEPAK SHARMA says:

Hi sir,

Could you please send the “INITIAL AND FINAL SETTING TIME OF READY MIX CONCRETE” FOR ALL THE GRADE OF CONCRETE.

Thanks and waiting for reply as soon as possible
Regards
Deepak sharma

Kuldeep prajapati says:

How we calculate slump of any grade ?

Yaazhvizhi says:

How to understand the correction factor in mix design to easy way

M.Z.Hussain says:

Why Standard deviation is considered as 1.91 where as it should be assumed as 5 for M35

Deepak Kumar says:

Send me the detail ofM35 design mix

Kelly Boston mushitu says:

Thanks for the update

ashu says:

its really usefull i am constructing cement packing plant and fcu=35n/mm2 can i use this as m35

Afaque Alam says:

Who much slump is required for m35 grade?

Leave a Reply

Your email address will not be published. Required fields are marked *

Ask a question