Parameters for mix design M40

Grade Designation = M-40
Type of cement = O.P.C-43 grade
Brand of cement = Vikram ( Grasim )
Admixture = Fosroc ( Conplast SP 430 G8M )
Fine Aggregate = Zone-II
Sp. Gravity Cement = 3.15
Fine Aggregate = 2.61
Coarse Aggregate (20mm) = 2.65
Coarse Aggregate (10mm) = 2.66
Minimum Cement (As per contract) = 400 kg / m3
Maximum water cement ratio (As per contract) = 0.45

Mix Calculation: –

1. Target Mean Strength = 40 + (5 X 1.65) = 48.25 Mpa

2. Selection of water cement ratio:-
Assume water cement ratio = 0.4

3. Calculation of cement content: –
Assume cement content 400 kg / m3
(As per contract Minimum cement content 400 kg / m3)

4. Calculation of water: –
400 X 0.4 = 160 kg Which is less than 186 kg (As per Table No. 4, IS: 10262)
Hence o.k.

5. Calculation for C.A. & F.A.: – As per IS : 10262 , Cl. No. 3.5.1

V = [ W + (C/Sc) + (1/p) . (fa/Sfa) ] x (1/1000)

V = [ W + (C/Sc) + {1/(1-p)} . (ca/Sca) ] x (1/1000)

Where

V = absolute volume of fresh concrete, which is equal to gross volume (m3) minus the volume of entrapped air ,

W = mass of water ( kg ) per m3 of concrete ,

C = mass of cement ( kg ) per m3 of concrete ,

Sc = specific gravity of cement,

(p) = Ratio of fine aggregate to total aggregate by absolute volume ,

(fa) , (ca) = total mass of fine aggregate and coarse aggregate (kg) per m3 of
Concrete respectively, and

Sfa , Sca = specific gravities of saturated surface dry fine aggregate and Coarse aggregate respectively.

As per Table No. 3 , IS-10262, for 20mm maximum size entrapped air is 2% .

Assume F.A. by % of volume of total aggregate = 36.5 %

0.98 = [ 160 + ( 400 / 3.15 ) + ( 1 / 0.365 ) ( Fa / 2.61 )] ( 1 /1000 )

=> Fa = 660.2 kg

Say Fa = 660 kg.

0.98 = [ 160 + ( 400 / 3.15 ) + ( 1 / 0.635 ) ( Ca / 2.655 )] ( 1 /1000 )

=> Ca = 1168.37 kg.

Say Ca = 1168 kg.

Considering 20 mm : 10mm = 0.6 : 0.4

20mm = 701 kg .
10mm = 467 kg .

Hence Mix details per m3

Cement = 400 kg
Water = 160 kg
Fine aggregate = 660 kg
Coarse aggregate 20 mm = 701 kg
Coarse aggregate 10 mm = 467 kg
Admixture = 0.6 % by weight of cement = 2.4 kg.
Recron 3S = 900 gm

Water: cement: F.A.: C.A. = 0.4: 1: 1.65: 2.92

Advertisements

Observation: –
A. Mix was cohesive and homogeneous.
B. Slump = 110mm
C. No. of cube casted = 12 Nos.
7 days average compressive strength = 51.26 MPa.
28 days average compressive strength = 62.96 MPa which is greater than 48.25MPa

Hence the mix is accepted.

We are thankful to Er Gurjeet Singh for this valuable information.

More Entries :
Comments
  • azee July 25, 2010 at 11:59 pm

    hi sir
    i need to know the correct propotions for these grades of concrete,so please kind enough to send me the propotion of materials for this grades

  • satish July 29, 2010 at 1:07 am

    sub
    i want to know how many types of design mix grades in making of cement concrete blocks and also its details i want

  • riyaz basha July 29, 2010 at 8:44 am

    sir, I want the BIS codes for hollow block concrete.Please sent it to my mail id.

  • Salil Sharma August 11, 2010 at 4:58 am

    Dear Sir,

    if i wish to use 40mm MSA then what changes do we have to incorporate in M-40 Mix.

  • madhur viajywargia August 21, 2010 at 2:21 pm

    i want to know is there any comments in irc book for repair of concrete m 40 grade by bitumunus seal coat,please give me page no. in the book

  • RAJKUMAR. M August 22, 2010 at 2:34 pm

    Dear sir,
    we performed a C40 SRPC mix Design, but we are unable to get a correct slump. can you suggest me that correct mix proportions. and could you please mail me?
    we used a water cement ratio 0.45 %

    • mohit October 22, 2010 at 8:04 pm

      dear enterprenuer, i think u do not use any plasticizer,you can get best results by using any plasticizer .it will cost a very little cost but the results will be very good.

  • om prakash sharma September 14, 2010 at 10:27 am

    sir, i work for pre stressed concrete pole factory kindly explain correct ratio while using only 10/12 mm metal .what shall be the difference if ops53 is used in place of opc 43 please advice

  • a.selva September 16, 2010 at 7:25 am

    how to determine concrete materials tested at view ? give some tips

    • a.selva September 16, 2010 at 7:28 am

      at spot on seeing to determine cement , aggregrate are well qualified give some tips

  • ADARSH SHUKLA September 16, 2010 at 8:29 am

    hi
    I am Adarsh shukla if i have a draine disine in village side over of pool of which have 100mm daya so what kinds of mix concreet disine we have to done the work of draine

  • neeraja November 12, 2010 at 1:05 pm

    may i known the mix design for ultra thin overlay with fiber polypropylene( obtained from cement bags) .

  • eng.Abdulellah December 4, 2010 at 5:04 pm

    Dear sir
    plz send to me the mix design of hollow block

  • shemy s babu January 4, 2011 at 12:43 am

    dear sir
    plz send to me the mix design of hollow block for my project work

    Reply

  • imran khan March 12, 2011 at 5:54 am

    Dear All, please advise me the M-40 mix designe for the concrete paver block. thanks

  • V.S.INDUSTRIES March 22, 2011 at 7:03 am

    dear sir
    pls send me mixing ratio of m-10 under ground drinage brick using material 10mm, 6mm,dust, cement, flyash and also advise me the mixing ratio for m-45

  • rakesh chaudhary April 25, 2011 at 12:40 am

    please send about rate analysis of M30,M40,M50,M60 grade of concerete

  • Ananth Kumar.M June 12, 2011 at 3:49 am

    Respected Sir Please send me the how to maintain the Conisistancy

  • neelam June 30, 2011 at 6:43 am

    please Tell me Laying tem of M40 Concrete.

  • A. suresh June 30, 2011 at 7:50 am

    I want how meny types of mix design and I want all type of mix design ratio

  • deepesh July 4, 2011 at 9:49 am

    sir i need M15, M25, M30, M40, M50 mix designs for making paver blocks( interlocking pavers)
    i using cement 53G opc and 6mm metal, sand and also quary dust. pls send me a mix design in
    kg
    thanks

  • janarthanan July 14, 2011 at 8:16 am

    sub
    i want to know how many types of design mix grades in making of cement concrete blocks and also its details i want

  • Post a comment

1 2 3 4 5 6 8